COOLING TOWER

 

ECOsmarte® treatment reduces the need for chemical additives to the cooling tower water. In a properly installed and maintained system, bacterial counts are reduced, with a subsequent minimization of the build-up of biofilm on heat exchanger surfaces. The resulting reduction in energy use, increased cooling tower operating efficiency and reduced maintenance effort provide cost savings as well as environmental benefit and regulatory compliance with respect to discharge of wastewater from blowdown. Cooling towers associated with chillers for air-conditioning should immediately consider the purchase of an ECOsmarte Point-of-Entry system to limit the corrosive sodium entering the equipment.

 ECOsmarte® Cooling Tower System

A cooling tower functions to cool a circulating stream of water. The tower acts as a heat exchanger by driving ambient air through falling water, causing some of the warmed water to evaporate (evaporation gives off heat -- providing cooling) and then circulates cooler water back through whatever equipment needs cooling (such as a chiller condenser). Typically, chemicals such as chlorine and chelating agents are added to cooling tower water to control biological growth (called "biofilm") and inhibit mineral build-up (called "scale"). The control of biofilm and scale is essential in maintaining cooling tower heat transfer efficiency. As the water volume in the tower is reduced through evaporation and drift, the concentration of these chemicals and their byproducts increases. Cooling towers also pick up contaminants from the ambient air. To maintain chemical and contaminant concentrations at a prudent level, water is periodically removed from the system through a process called "blowdown" or "bleed off."


The blowdown water and the water lost through evaporation and drift are replaced with fresh "make-up" water (which also contains minerals and other impurities). Blowdown water must subsequently be discharged to a local wastewater treatment facility or discharged onsite to the environment. The blowdown water typically contains little organic material, and the local wastewater treatment facility will charge extra sewage fees for accepting the water.  These costs can be quite significant in the overall costs of operating a cooling tower. Discharge of the blowdown water to the environment onsite is coming under increasing regulation because of the contaminants typically found in blowdown water. Oxygen will dissipate quickly and not be found in the blowdown water. This reduces the overall chemical load found in the discharge water, making it easier to comply with regulations. 

Most ECOsmarte® Cooling Tower Systems include the following components: water and oil coalescing filters, particle filter, oxygen anodes, copper anodes, and a monitoring/control system. 

Field experience has demonstrated that the use of oxygen and ionization in place of chemical treatment can reduce the need for blowdown, and, in some cases when make-up water and ambient air are relatively clean, can eliminate it. As a result, cost savings accrue from decreased chemical and water use requirements as well as from a reduction of wastewater volume. There are also environmental benefits as fewer chlorine or chlorinated compounds and other chemicals are discharged. An ECOsmarte® Oxygen/Copper System should require less maintenance per year than either a chemical or chemical/ozone system. 

There is substantial evidence that ionization combined with oxygen acts as a descaling agent. The premise is that oxygen oxidizes the biofilm that serves as a binding agent adhering scale to heat exchange surfaces. When scale build-up on condenser tubes is reduced, higher heat transfer rates are achieved. Increasing the condenser heat transfer rate reduces the chiller head pressure, which then allows the chiller to operate more efficiently and consumes less energy. Certain calcium and magnesium carbonate revert and maintain a bicarbonate state to as high as 150° in ECOsmarte's field experience. 

If pH control is required the ECOsmarte Programmable Tower System can automate the injection of either carbon dioxide or acid.

 

Ionization, in addition to traditional chemical water treatment methods;

 

• Substantially reduce or eliminate the cost of water treatment chemicals and their associated costs for insurance, storage, handling and disposal.


• Reduce the amount of water used in open cooling water operation and the associated cost for supply and discharge.


• Eliminate discharge of toxic chemicals.


• Facilitate EPA & OSHA compliance by eliminating chemicals, both in facilities and wastewater.


• Treat water for applications where the use of chemicals is either too costly or the application itself prohibits their use.


• Descale systems, which have lost efficient heat transfer, without the need for rodding or acid cleaning.


• Eliminate algae and bacteria, including difficult problems such as yeast and Legionella, by the use of a simple and very effective ionization unit, recognizing existing world class science.


• Provide redundant capability and dual
protection, with best available technology.

 

 Chemical, Scale and Corrosion Control

 

A Non-Salt, Non-Chemical, World-Class viral and microbial kill is maintained in the tower.
 
Scale and corrosion control is achieved with the addition of
ionization and oxygen electrodes.
 
ECOsmarte® manages the stability and solubility indexes for calcium, magnesium, bicarbonates, carbonates and silicates which are directly responsible for scale, deposit and corrosion problems in cooling towers.

The ECOsmarte® System produces strong coagulation and flocculation throughout the tower. Coagulation and proper filtration control colloidal organics, silt, dirt and insoluble metals that produce galvanic corrosion, increased maintenance
and down time.

ECOsmarte® Cooling Tower and Point–of-Entry Installs Non-salt, non-chemical bacteria, scale and process under control.

 

 

Point-Of-Entry Carbon Tower for 60-150 GPM chemical removal on this site. Low 0.1-0.3 ppm copper residual placed in the water controlling scale and bacterial control throughout the plant.


 

 

Programmable Tower Controller maintains 0.4ppm to 0.7ppm ionic copper residual in water, controlling fusaria, algae, ecoli, coliform and nematodes, items the
biocide could not control.  Tower size 60 tons maximum size available 1000 tons for 2004.

 

 
White Hydroxite
Filters sidestreamed to
handle process and chiller water, operating at 10-20 microns without flow restriction and absorbing heavy metals.  High Flow rate low pressure to 400 GPM.

 

Point-Of-Entry Control Box  Versions available to accommodate 50 to
3500 TDS, ranging
from ultra pure water in semiconductor / circuit applications to recirculated wastewater to be used in the process

 


GE/Osmonics has
engineered the ECOsmarte® Magnum Commercial Valve, each capable of 90 GPM.

 

Three Controllers drive Six Chambers (3 Copper/Oxygen;
3 Oxygen Only). NOTE: 6" ductile iron pipe and 3x200 ton site, oxygen is scavenged by carbon at this site.

 

Programmable Tower Controller maintains 0.1ppm to 0.4ppm ionic copper residual in water, controlling fusaria, algae, and nematodes, items the biocide could not control.  Tower size 60 tons, CO2 ph control available, not used on this site.

 

 

ECOsmarte® Chemical-Free Mini-Tower 1 1/2” System Manous Plastics in Dallas, Texas.

Installed ECOsmarte® 1 1/2” Standard 1 Ton Cooling Tower System, 2/96 Water quality shows major improvement; Tower down time reduced dramatically and no chemicals are used in this tower. Customer testimonial available, 1996 install date


 

pH management:  None, bump in pH 8.3 to 9.0
Source pH 2.8

TDS Source Water:  670

TDS Tower Water:  (testing not needed) 3300 actual at 1 year

Calcium ppm Source:  340 (20 grains of hardness)

PSI:  80

Sump Size:  600 gallons

Filtration:  Sediment pore-filter, granular activated carbon

Electrical:  110V, 30 VA with automatic backwash every 7 days

Make-Up Volume:  100 gallons per week

Ionization Hours:  96 hours/month run consecutively, 4 days out of 30

Target Copper Level:  0.3 ppm

Oxygen Hours:  Continual

Chemicals Used:  None

Cost of system:  $9,995.00 installed with GAC side stream filter

Primary Benefits:  Zero down time, Zero scale, complete elimination of chemical treatment.  Water in injection molding equipment is also scale free.

 

Evaporative Coolers and Chillers commonly require identical systems to towers. They have been successfully installed since 1997 on metal fabrication plants, semi-comductor plants, extrusion molding and injection molding facilities. The treated rooftop water can often be used in the process.

 

 

 

 

 With ozone and ionization gaining acceptance in cooling tower water treatment, ECOsmarte® ionic copper and natural oxygen systems provide the best available technologies for cooling tower management. Oxygen radicals (OH and O2) from the water itself provide more powerful, less corrosive oxidizers than ozone and are enhanced by the residual sanitizer, ionic copper. ECOsmarte® oxygen and residual ionic copper act as a  powerful biocide that decreases or nearly eliminates the need to remove quantities of water from the cooling tower in order to decrease the concentration of organic and mineral solids in the system.


 

 

 

FILTER STRATEGIES
POINT OF ENTRY : GAC on Municipal Water, GAC and Hydroxite on Well Water

 

SIDE STREAM OF TOWER SUMP GAC (to scavenge oxygen) and or GLASS PACK™ Media

(Holding ponds require additional independent controls. ECOsmarte commonly works in conjunction with existing equipment.

pH STRATEGIES
CARBON DIOXIDE Carbon dioxide in minutes or hours per day can adjust pH in the sump or in tower makeup water. Conventional acid deeds driven by sensor and compatible with the ECOsmarte programmable controller.